      TERMSTAR 2000 ESS
      2.3 mb, PDF
      TERMSTAR 2000 Blue Line CR
      2.3 mb, PDF
      TERMSTAR 2000 Blue Line
      2.3 mb, PDF
      Leaflet TS 3000
      2.3 mb, PDF

    TERMSTAR 2000

    Termstar 2000 radiant heating system is a modern, direct radiant, high-efficiency infrared heater that offers:

    • The most efficient heating of industrial and warehouse premises
    • Immediate availability of the heating system and quick achievement of the operational temperature
    • Long lifespan and operational reliability, which is ensured by using the state-of-the-art materials and components
    • Minimization of gas distribution costs and number of emission points

    Excellent radiation with an efficiency of 80-85%, achieved by using thermal insulation, intensive recirculation of flue gas (the flue gas is rotated several times in the duct system and then exits through the flue pipe into the outer space) and an optimal shape solution with a direct-radiation effect.
    Reduced surface temperature of the radiator achieved by recirculation is important in terms of the “softness” of the radiant component and in terms of the lower thermal load of the materials.
    An integrated high performance overpressure burner with single-stage or two-stage (ESS, Blue Line) or continuous (Blue Line CR) power control and programmable control is equipped with recuperation system that increases its outstanding efficiency to as much as 103%.

    Modular system with easy and fast assembly

    The radiant system is insulated on top and on sides, which prevents heat from escaping above the infrared heater.

    TERMSTAR 2000 Blue Line CR

    TERMSTAR 2000

    Heating system with exhaust gas recirculation, recuperation and continuous control.

    TERMSTAR 2000 Blue Line CR

    TS 31 CR

    TS 37 CR

    TS 45 CR

    TS 50 CR

    TS 65 CR

    TS 80 CR

    TS 100 CR

    Burner power /kW/

    25-31

    26-37

    29-45

    37-50

    45-65

    55-80

    65-100

    Gas consumption ZP /m3/h/

    2,6-3,3

    2,8-3,9

    3,1-4,8

    3,9-5,3

    4,8-6,8

    5,7-8,4

    6,8-10,5

    Gas consumption PB /kg/h/

    1,9-2,4

    2,0-2,9

    2,3-3,5

    2,9-3,9

    3,5-5

    4,3-6,2

    5-7,75

    Length range of 2R radiator /m/

    10-16

    16-20

    18-24

    20-36

    24-36

    28-42

    28-42

    Power regulation

    continuous

    Inlet gas pressure /kPa/

    2,2-5

    Gas connection

    1/2“ external thread

    3/4“ external thread

    Flue diameter /mm/

    100

    113

    Power supply

    230V/50Hz * 1,1 A * 250VA

    Efficiency /%/

    98 - 103%

    Ratio max./min. of the energy emitted along the radiator

    2:1

    Ref. length of the radiator 2R system /m/

    12

    16

    20

    24

    28

    30

    30

    Length range of the 2R radiator /m/

    10-16

    14-20

    18-24

    20-28

    24-32

    28-42

    28-42

    Weight of the 2R system /kg/m/

    16,5

    19,5

    26,5

    Ref. length of the ÍR system /m/

    24

    32

    40

    48

    56

    64

    64

    Length range of the 1R radiator /m/

    20-32

    28-40

    36-48

    40-56

    48-64

    56-76

    56 - 76

    Weight of the 1R system /kg/m/

    12

    14

    16

    TERMSTAR 2000 Blue Line

    TERMSTAR 2000

    Heating system with exhaust gas recirculation and recuperation.

    TERMSTAR 2000 Blue Line

    TS 31 R

    TS 37 R

    TS 45 R

    TS 50 R

    TS 65 R

    TS 80 R

    TS 100 R

    Burner power /kW/

    25-31

    26-37

    29-45

    37-50

    45-65

    55-80

    65-100

    Gas consumption ZP /m3/h/

    2,6-3,3

    2,8-3,9

    3,1-4,8

    3,9-5,3

    4,8-6,8

    5,7-8,4

    6,8-10,5

    Gas consumption PB /kg/h/

    1,9-2,4

    2,0-2,9

    2,3-3,5

    2,9-3,9

    3,5-5

    4,3-6,2

    5-7,75

    Length range of 2R radiator /m/

    10-16

    16-20

    18-24

    20-36

    24-36

    28-42

    28-42

    Power regulation

    one ore two-stage

    Inlet gas pressure /kPa/

    2,2-5

    Gas connection

    1/2“ external thread

    3/4“ external thread

    Flue diameter /mm/

    100

    113

    Power supply

    230V/50Hz * 1,1 A * 250VA

    Efficiency /%/

    98 - 103%

    Ratio max./min. of the energy emitted along the radiator

    2:1

    Ref. length of the radiator 2R system /m/

    12

    16

    20

    24

    28

    30

    30

    Length range of the 2R radiator /m/

    10-16

    14-20

    18-24

    20-28

    24-32

    28-42

    28-42

    Weight of the 2R system /kg/m/

    16,5

    19,5

    26,5

    Ref. length of the ÍR system /m/

    24

    32

    40

    48

    56

    64

    64

    Length range of the 1R radiator /m/

    20-32

    28-40

    36-48

    40-56

    48-64

    56-76

    56 - 76

    Weight of the 1R system /kg/m/

    12

    14

    16

    TERMSTAR 2000 ESS

    TERMSTAR 2000

    Heating system with exhaust gas recirculation.

    TERMSTAR 2000 ESS

    TS 31 ESS

    TS 37 ESS

    TS 45 ESS

    TS 50 ESS

    TS 65 ESS

    TS 80 ESS

    TS 100 ESS

    Burner power /kW/

    25-31

    26-37

    29-45

    37-50

    45-65

    55-80

    65-100

    Gas consumption ZP /m3/h/

    2,6-3,3

    2,8-3,9

    3,1-4,8

    3,9-5,3

    4,8-6,8

    5,7-8,4

    6,8-10,5

    Gas consumption PB /kg/h/

    1,9-2,4

    2,0-2,9

    2,3-3,5

    2,9-3,9

    3,5-5

    4,3-6,2

    5-7,75

    Flue gas temperature in /°C/

    125-225

    Power regulation

    one or two-stage

    Inlet gas pressure /kPa/

    2,2-5

    Gas connection

    1/2“ external thread

    3/4“ external thread

    Flue diameter /mm/

    100

    113

    Power supply

    230V/50Hz * 1,1 A * 250VA

    Efficiency at ref. length /%/

    92+ (A+)

    Ratio max./min. of the energy emitted along the radiator

    2:1

    Ref. length of the radiator 2R system /m/

    12

    16

    20

    24

    28

    30

    30

    Length range of the 2R radiator /m/

    10-16

    14-20

    18-24

    20-28

    24-32

    28-42

    28-42

    Weight of the 2R system /kg/m/

    16,5

    19,5

    26,5

    Ref. length of the ÍR system /m/

    24

    32

    40

    48

    56

    64

    64

    Length range of the 1R radiator /m/

    20-32

    28-40

    36-48

    40-56

    48-64

    56-76

    56 - 76

    Weight of the 1R system /kg/m/

    12

    14

    16

    Shapes of the infrared heaters

    • Shape ( I ) direct dual pipes
    • Shape ( L ) dual pipes with one bend on the right or left side to cover the area
    • Shape ( U ) dual pipes with two bends for wide premises, allows placement of more systems in sequence along the premises
    • Shape ( O ) single pipe system for low ceiling and wider premises with optimal radiation distribution of the floor, for halls with lower energy demands and large area

    Height of the radiator placement

    TERMSTAR 2000
    – min 3 m above the floor surface, mounted on the wall, tilting of the radiator 10 degrees from the surface towards the heated area
    – min 3.5 m above the floor when placed horizontally under the ceiling

    Flue gas drainage and air suction

    The flue gases from the TERMSTAR 2000 burner unit are always connected to the smoke flue pipe, through which the flue gases are drained out of the premises. The smoke flue can lead to the exterior through the ceiling or wall of the object. Smoke flues can be single-walled, double-walled with insulation for high chimneys, or coaxial to provide air suction from outside. Standard air suction intake for combustion is from the inner space of the object, or it is possible to use fresh air from outside.

    TYPE

    CONNECTION DIAMETER OF THE CHIMNEY

    CONNECTION DIAMETER OF THE AIR SUCTION

    TERMSTAR 2000 ESS to 50 kW

    DN 100

    DN 100

    TERMSTAR 2000 ESS above 50 kW

    DN 113

    DN 125

    TERMSTAR 2000 BLUE LINE a BLUE LINE CR above 50 kW

    DN 113

    DN 125

    Gas connection in kPa

    Type

    max [kPa]

    Recommendation [kPa]

    Ball valve

    TERMSTAR 2000 to 50 kW

    6,0

    2,2 - 4,5

    DN 16

    TERMSTAR 2000 above 50 kW

    6,0

    2,2 - 4,5

    DN 20

    • ABOUT COMPANY

      ELTERM s.r.o.

      Since its incorporation, Elterm s.r.o. is focused on development, production and sale of gas infrared heaters. Experienced team of out experts is always ready to help and provide valuable advice on how to create and achieve optimal and convenient temperature in various production facilities.

    • MAIN MENU

      • ABOUT US
      • PRODUCTS
      • SERVICE
      • DESIGN
      • CERTIFICATES
      • REFERENCES
      • PARTNERS
      • CONTACT
    • CONTACT

      Our customer support is always available to you.

      Bratislavská 87
      902 04 Pezinok
      Slovak republic

      +421 33 6422 539

      elterm@elterm.sk

    • OUR PRODUCTS

      • TERMSTAR 2000
      • TERMSTAR 3000
      • RECUPERATOR
    © 2017 Elterm s.r.o. | All rights reserved | Website design by: gr8design s.r.o.
    Top